ELECTRODE SETTINGS
Inspection of all wires, spring
contacts and electrodes should
be done periodically.
OIL BURNER AIR BAND ADJUSTMENT
RAMTEQ sets oil burners at sea level. Air bands may need adjustment at higher elevations to
offer enhanced performance of the burner and extended life of the machine.
Adjustment of burner is done with pump motor and thermostat
set to maximum. Loosen locking screw on air band, then close
band until black smoke vents up exhaust vent. Take careful note
of air band position when black smoke is first noticed. Slowly
open air band until white smoke vents, then turn air band halfway
back to where black smoke was first noted. Tighten air band
locking screw. When properly set, the unit should NOT have either
"black" smoke or "white" smoke during operation.
IF BLACK OR WHITE SMOKE VENTS FROM EXHAUST
PORT UPON STARTING EQUIPMENT, DISCONTINUE USE
AND ADJUST AIR BANDS BEFORE RESTARTING.
PUMP MAINTENANCE
Fill crankcase to dot on oil gauge window per specifications with the specific oil recommended by the
pump manufacturer. Ensure the right oil for specific pump as it may vary.
Change oil after 50 Hour Break-in Period.
Change oil at every 500 Hour Intervals thereafter.
UNLOADER ADJUSTMENT
This RAMTEQ machine has the unloader correctly set at the the factory. Setting an unloader
is a difficult job without the proper equipment and training. Should the need arise to change the unloader
settings, please contact your local dealer.
Maintenance Instructions
AMAZING MACHINERY 2288 GUNBARREL ROAD, SUITE 111151 CHATTANOOGA, TENNESSEE 37421 PHONE: 18005047435 FAX: 18005047436
RAMTEQ
®
1 4275 NORTHWES T F R E E WAY H O U S TON, T X 7 7040 P H ONE: 713.98 3.6000 FAX: 713.98 3.6405 300-00010-01 7/06
OPeratOr’s Manual
30585 P R O G R ESSIVE WAY A BBOT S F O R D B C,V2 T 6W3 PHONE: 604.850. 6662 T O L L FREE 800 . 663. 8 331 FAX: 604.85 0.8 886 9/07
Page 5
RAMTEQ
®
1 4275 NORTHWES T F R E E WAY H O U S TON, T X 7 7040 P H ONE: 713.98 3.6000 FAX: 713.98 3.6405 300-00012-01 3/08
Kommentare zu diesen Handbüchern